RESEARCH · R4
In progress
GPU node thermal twins
CFD geometry for Theta
- Area
- Research
- Role
- Designer
- Context
- Theta research program
- Team
- Theta research program
- Dates
- Jul 2026
- Status
- In progress
- Tools
- replicad (OpenCascade), STEP and STL export, SimScale (OpenFOAM), k-omega SST
The problem
Theta found that a GPU’s slot on the baseboard alone shifts healthy readings. A thermal twin of the node should reproduce that pattern from airflow geometry and show which faults can cause the large shifts Theta flags.
What I built
- Geometry generated in code for a 4 × A100 node and an 8 × H100 SXM5 HGX node (177 named solids on the 2 × 4 reference layout), exported to STEP and STL.
- A 21.5 million cell conjugate heat transfer run of the A100 twin on SimScale.
- A field autopsy of that run and a fix list the H100 twin is built on: explicit plate fins, an effective-conductivity TIM layer, a flush fluid domain, and convergence that is actually checked.

Results
21.5Mcells in the first run
177named solids, H100 twin
PendingH100 run
What I learned
The first run completed but predicted die temperatures of 279 to 443 °C, which no working GPU reaches. The autopsy traced it to how the geometry and materials were posed, and showed that iteration 1000 was only where the run stopped, not proof of convergence.